Skip to Main Content
FlightPushFLIGHTPUSH
Part 29

Learn

Dashboard My Courses Mastery Map Practice Flight Bag

Resources

CFR & AIM FAA Orders Handbooks & Guides Certification Standards Pilot/Controller Glossary Advisory Circulars Legal Interpretations
Safety Center
Articles Trust Center
Help Center FAQ Status
  1. Reference Library
  2. CFR & AIM
  3. CFR
  4. Part 29
  5. § 29.967
Loading
flightpush.co home

14 CFR · Part 29

14 CFR § 29.967

Fuel tank installation.

← Previous SectionNext Section →
Read in Subpart E
Part 29 Contents
  • Subpart A: General
  • Subpart B: Flight
  • Subpart C: Strength Requirements
  • Subpart D: Design and Construction
  • Subpart E: Powerplant
  • Subpart F: Equipment
  • Subpart G: Operating Limitations and Information
  • Appendix A to Part 29: Instructions for Continued Airworthiness
  • Appendix B to Part 29: Airworthiness Criteria for Helicopter Instrument Flight
  • Appendix C to Part 29: Icing Certification
  • Appendix D to Part 29: Criteria for Demonstration of Emergency Evacuation Procedures Under § 29.803
  • Appendix E to Part 29: HIRF Environments and Equipment HIRF Test Levels
(a)

Each fuel tank must be supported so that tank loads are not concentrated on unsupported tank surfaces. In addition—

(1)

There must be pads, if necessary, to prevent chafing between each tank and its supports;

(2)

The padding must be nonabsorbent or treated to prevent the absorption of fuel;

(3)

If flexible tank liners are used, they must be supported so that they are not required to withstand fluid loads; and

(4)

Each interior surface of tank compartments must be smooth and free of projections that could cause wear of the liner, unless—

(i)

There are means for protection of the liner at those points; or

(ii)

The construction of the liner itself provides such protection.

(b)

Any spaces adjacent to tank surfaces must be adequately ventilated to avoid accumulation of fuel or fumes in those spaces due to minor leakage. If the tank is in a sealed compartment, ventilation may be limited to drain holes that prevent clogging and that prevent excessive pressure resulting from altitude changes. If flexible tank liners are installed, the venting arrangement for the spaces between the liner and its container must maintain the proper relationship to tank vent pressures for any expected flight condition.

(c)

The location of each tank must meet the requirements of § 29.1185(b) and (c).

(d)

No rotorcraft skin immediately adjacent to a major air outlet from the engine compartment may act as the wall of an integral tank.

Regulations Referenced

14 CFR 29.1185

Reflects the eCFR edition current as of September 29, 2026. Retrieved from ecfr.gov on October 16, 2026.

Primary Source

  • Official Source (14 CFR · Part 29)