Skip to Main Content
FlightPushFLIGHTPUSH
Part 29

Learn

Dashboard My Courses Mastery Map Practice Flight Bag

Resources

CFR & AIM FAA Orders Handbooks & Guides Certification Standards Pilot/Controller Glossary Advisory Circulars Legal Interpretations
Safety Center
Articles Trust Center
Help Center FAQ Status
  1. Reference Library
  2. CFR & AIM
  3. CFR
  4. Part 29
  5. § 29.807
Loading
flightpush.co home
Loading reference

14 CFR · Part 29

14 CFR § 29.807

Passenger emergency exits.

← Previous SectionNext Section →
Read in Subpart D
Part 29 Contents
  • Subpart A: General
  • Subpart B: Flight
  • Subpart C: Strength Requirements
  • Subpart D: Design and Construction
  • Subpart E: Powerplant
  • Subpart F: Equipment
  • Subpart G: Operating Limitations and Information
  • Appendix A to Part 29: Instructions for Continued Airworthiness
  • Appendix B to Part 29: Airworthiness Criteria for Helicopter Instrument Flight
  • Appendix C to Part 29: Icing Certification
  • Appendix D to Part 29: Criteria for Demonstration of Emergency Evacuation Procedures Under § 29.803
  • Appendix E to Part 29: HIRF Environments and Equipment HIRF Test Levels
(a)

Type. For the purpose of this part, the types of passenger emergency exit are as follows:

(1)

Type I. This type must have a rectangular opening of not less than 24 inches wide by 48 inches high, with corner radii not greater than one-third the width of the exit, in the passenger area in the side of the fuselage at floor level and as far away as practicable from areas that might become potential fire hazards in a crash.

(2)

Type II. This type is the same as Type I, except that the opening must be at least 20 inches wide by 44 inches high.

(3)

Type III. This type is the same as Type I, except that—

(i)

The opening must be at least 20 inches wide by 36 inches high; and

(ii)

The exits need not be at floor level.

(4)

Type IV. This type must have a rectangular opening of not less than 19 inches wide by 26 inches high, with corner radii not greater than one-third the width of the exit, in the side of the fuselage with a step-up inside the rotorcraft of not more than 29 inches.

Openings with dimensions larger than those specified in this section may be used, regardless of shape, if the base of the opening has a flat surface of not less than the specified width.

(b)

Passenger emergency exits; side-of-fuselage. Emergency exits must be accessible to the passengers and, except as provided in paragraph (d) of this section, must be provided in accordance with the following table:

Passenger seating capacityEmergency exits for each side of the fuselage
Type IType IIType IIIType IV
1 through 101
11 through 191 or2
20 through 3911
40 through 5911
60 through 7911 or2
(c)

Passenger emergency exits; other than side-of-fuselage. In addition to the requirements of paragraph (b) of this section—

(1)

There must be enough openings in the top, bottom, or ends of the fuselage to allow evacuation with the rotorcraft on its side; or

(2)

The probability of the rotorcraft coming to rest on its side in a crash landing must be extremely remote.

(d)

Ditching emergency exits for passengers. If certification with ditching provisions is requested, ditching emergency exits must be provided in accordance with the following requirements and must be proven by test, demonstration, or analysis unless the emergency exits required by paragraph (b) of this section already meet these requirements.

(1)

For rotorcraft that have a passenger seating configuration, excluding pilots seats, of nine seats or less, one exit above the waterline in each side of the rotorcraft, meeting at least the dimensions of a Type IV exit.

(2)

For rotorcraft that have a passenger seating configuration, excluding pilots seats, of 10 seats or more, one exit above the waterline in a side of the rotorcraft meeting at least the dimensions of a Type III exit, for each unit (or part of a unit) of 35 passenger seats, but no less than two such exits in the passenger cabin, with one on each side of the rotorcraft. However, where it has been shown through analysis, ditching demonstrations, or any other tests found necessary by the Administrator, that the evacuation capability of the rotorcraft during ditching is improved by the use of larger exits, or by other means, the passenger seat to exit ratio may be increased.

(3)

Flotation devices, whether stowed or deployed, may not interfere with or obstruct the exits.

(e)

Ramp exits. One Type I exit only, or one Type II exit only, that is required in the side of the fuselage under paragraph (b) of this section, may be installed instead in the ramp of floor ramp rotorcraft if—

(1)

Its installation in the side of the fuselage is impractical; and

(2)

Its installation in the ramp meets § 29.813.

(f)

Tests. The proper functioning of each emergency exit must be shown by test.

Regulations Referenced

14 CFR 29.813

Reflects the eCFR edition current as of September 29, 2026. Retrieved from ecfr.gov on October 16, 2026.

Primary Source

  • Official Source (14 CFR · Part 29)