14 CFR · Part 29

14 CFR § 29.685

Control system details.

← Previous SectionNext Section →
Read in Subpart D
Part 29 Contents
  • Subpart A: General
  • Subpart B: Flight
  • Subpart C: Strength Requirements
  • Subpart D: Design and Construction
  • Subpart E: Powerplant
  • Subpart F: Equipment
  • Subpart G: Operating Limitations and Information
  • Appendix A to Part 29: Instructions for Continued Airworthiness
  • Appendix B to Part 29: Airworthiness Criteria for Helicopter Instrument Flight
  • Appendix C to Part 29: Icing Certification
  • Appendix D to Part 29: Criteria for Demonstration of Emergency Evacuation Procedures Under § 29.803
  • Appendix E to Part 29: HIRF Environments and Equipment HIRF Test Levels
(a)

Each detail of each control system must be designed to prevent jamming, chafing, and interference from cargo, passengers, loose objects, or the freezing of moisture.

(b)

There must be means in the cockpit to prevent the entry of foreign objects into places where they would jam the system.

(c)

There must be means to prevent the slapping of cables or tubes against other parts.

(d)

Cable systems must be designed as follows:

(1)

Cables, cable fittings, turnbuckles, splices, and pulleys must be of an acceptable kind.

(2)

The design of cable systems must prevent any hazardous change in cable tension throughout the range of travel under any operating conditions and temperature variations.

(3)

No cable smaller than 1/8 inch diameter may be used in any primary control system.

(4)

Pulley kinds and sizes must correspond to the cables with which they are used. The pulley-cable combinations and strength values specified in MIL-HDBK-5 must be used unless they are inapplicable.

(5)

Pulleys must have close fitting guards to prevent the cables from being displaced or fouled.

(6)

Pulleys must lie close enough to the plane passing through the cable to prevent the cable from rubbing against the pulley flange.

(7)

No fairlead may cause a change in cable direction of more than three degrees.

(8)

No clevis pin subject to load or motion and retained only by cotter pins may be used in the control system.

(9)

Turnbuckles attached to parts having angular motion must be installed to prevent binding throughout the range of travel.

(10)

There must be means for visual inspection at each fairlead, pulley, terminal, and turnbuckle.

(e)

Control system joints subject to angular motion must incorporate the following special factors with respect to the ultimate bearing strength of the softest material used as a bearing:

(1)

3.33 for push-pull systems other than ball and roller bearing systems.

(2)

2.0 for cable systems.

(f)

For control system joints, the manufacturer's static, non-Brinell rating of ball and roller bearings may not be exceeded.

Reflects the eCFR edition current as of September 29, 2026. Retrieved from ecfr.gov on October 16, 2026.

Primary Source

  • Official Source (14 CFR · Part 29)