NTSB · Safety Recommendation
Safety Recommendation A-74-011
Recommendation
REQUIRE A MORE ACCESSIBLE LOCATION FOR THE PORTABLE OXYGEN UNITS IN THE LOWER LOBE GALLEY OF ALL DC-10 AIRCRAFT AND RELOCATE PORTABLE OXYGEN UNITS IN ALL OTHER AIRCRAFT, WHERE REQUIRED, TO ENSURE ACCESSIBILITY OF PORTABLE OXYGEN UNITS AND COMPLIANCE WITH THE FAR'S
Safety Issue and Context
The National Transportation Safety Board 1 s continuing investigation of the National .Airlines DC-10 accident near Albuquerque, New Mexico, on November 3, 1973, has disclosed unsafe conditions in the passenger oxygen system, portable oxygen system, and cabin pressurization system. The Board believes that these unsafe conditions merit your immediate attention and the attentions of all air carriers which operate aircraft with this equipment.
When the aircraft lost a cabin window and the passenger cabin decompressed, many of the passenger's oxygen-generating units were activated. Three oxygen canisters came out of their mountings in the seatback oxygen compartment and fell onto passenger seat cushions. Two of these canisters, which become very hot when operating, scorched the cushions and burned fingers when seat occupants tried to remove them. The third reportedly caused a small fire. The canisters came out of their mounting brackets because of the pulling force exerted on either the initiation lanyard of the canisters or the oxygen supply hose.
The Safety Board believes that these canisters constitute a potential fire and injury hazard when they are not retained properly in their mountings.
Response History
June 16, 1977 · NTSB Correspondence · FAA
Closed--acceptable action.
February 21, 1974 · Recipient Response · FAA
THE FAA IS WORKING WITH DOUGLAS TO SELECT MORE ACCESSIBLE LOCATIONS FOR THE PORTABLE OXYGEN UNITS IN THE LOWER LOBE GALLEY. WHEN THE NEW LOCATIONS ARE DETERMINED, THEY WILL TAKE APPROPRIATE ACTION TO IMPLEMENT RELOCATION.