W&B · Chapter 3
W&B 3-3
Page 3-3
Figure 3-2. Ramp scales. Figure 3-3. Load cell scales. All scales for aviation use, manual or electronic, must be protected when stored or shipped, and they must be checked periodically for accuracy. The maximum recognized period between calibration checks is 12 months; however, this period may be reduced by an airworthiness authority dependent on the conditions of use. Scales in daily use may require a shorter interval and/or testing to determine the continued accuracy of the unit. Scales should be returned to the manufacturer for proper calibration and testing. Preparation for Weighing In general, weight procedures may vary with the aircraft and types of weight equipment employed. The weighing procedure contained in the manufacturer’s maintenance manual should be followed for each particular aircraft. The major considerations in preparing an aircraft for weighing are described in the following paragraphs. Scale Preparation Mechanical and electronic scales shall be inspected prior to use and set to zero. This is done by adding and removing a weight, then rechecking for zero. This process should be repeated until a steady zero setting is obtained. The scales should be located in the same environment in which they